= Teltonika UM62x1 = [[TOC(Internal/*)]] [http://www.teltonika.lt/en/pages/view/?id=1010 Teltonika UM62x1] == Linux == Device will look like a cdrom {{{ eject }}} If you install usb-modeswitch and usb-modeswitch-data then it will appear as a network interface and not USB storage by default, and you won't need to "eject" the device. Can use: {{{ wget --http-user admin --http-password admin -qO - http://192.168.0.1/cgi/cli?[command] }}} See data collection below for how to find a list of commands. == Embedded Linux == Verified working with Openwrt on Routerstation Pro. TODO: Complete kernel module list. Kernel has to be compiled with cdc_ether, scsi cdrom If using Openwrt, compile busybox with eject command or dmesg to find out what the device shows up as: {{{ opkg update opkg install sdparm sdparm --command=eject /dev/sg? }}} Then use the above Linux tutorial. == Windows == Verified working in Windows 7 64-bit Did not test without installing Teltonika software Install software when prompted to. == Mac OS == Verified working under Lion TODO. == Settings == After the device is set up, the USB device will appear as a wired Ethernet device with the, dhcp release, IP address of 192.168.0.x. 1. Favorite browser ==> 192.168.0.1 a. To login, press ctrl+shift and click on the Teltonika logo on the top of the web page. The default username for the administrative interface that we will be using is:[[BR]] Username: admin[[BR]] Password: EifAFKt8 2. Configure Wimax a. Click on WiMAX tab b. Click on Channels sub-tab c. Add your base station(s) information 3. Verify connectivity Note that your settings are stored on the device, so this will only have to be done once for each device. == Telnet == 1. telnet 700 a. Notice that above the port is 700[[BR]] Username: admin[[BR]] Password: admin01 2. To make change to files (At your own risk of making a paper weight): a. mount -o,remount,rw / == Data collection & Misc == One tab I would like to point out is the CLI (command line interface) that you can run several commands to collect all kinds of information. A list of commands can be viewed with the help command. There is also more options that you can get by typing in 'setuser su' and then type help. Output of help command (as Normal user): {{{ COMMAND HELP ============ CMD help Get help on commands RFC resetRfcSdcDbgStats reset rfcSdc dbg stats CBE showMacUl Show the MAC uplink configuration CBE showMacDl Show the MAC downlink configuration CBE showMacFrame Show the MAC frame configuration CBE showMacStatsRx Show MAC message reception statistics CBE showSsCaps Show negotiated capabilities of an SS CBE showCaps Show global capabilities CBE setCaps Set global capabilities CBE setHarqCategory Changes the *declared* HARQ category. CBE loadCalibrationFromHost Load calibration file from host CBE showSf Show SF information CBE createSf Declare a SF in the local SFD CBE changeSf Change a SF in the local SFD CBE deleteSf Delete a SF in the local SFD CBE setSfEnable Enable/disable a SF in the local SFD CBE showPhsSf Show PHS rules for Sf creation CBE createPhsSf Create/change PHS rules for Sf creation CBE deletePhsSf Delete PHS rules for Sf creation CBE setMii Set MII link configuration CBE showMii Show the MII configuration CBE showTime Show the current time CBE filterLog filter logging. Syntax is '(+/-)MOD[/SUB]'. '*' is supported at the end. CBE enableLog Enable logging. Syntax is 'MOD[/SUB]'. CBE disableLog Disable logging. Syntax is 'MOD[/SUB]'. CBE showLog show logging state. Syntax is 'MOD[/SUB]'. '*' is supported CBE suppressLogWarnings Enable/Disable warnings from disabled logs CBE enableSniffer enable packet sniffing CBE setSnifferVerbose set verbose level for the packet dumping CBE setSnifferParams set the sniffer parameters CBE disableSniffer disable packet sniffing CBE showSniffer show sniffer state and filters CBE clearSnifferFilters clear all sniffer filters CBE createSnifferFilter create a new sniffer filter CBE deleteSnifferFilter remove the specified filter from the sniffer CBE showMacAddress Show the mac address CBE setFatalErrorMode Set value of fatal error mode CBE showFatalErrorMode Show value of fatal error mode CBE showPkmCs Show pkm settings related to crypto suites CBE setPkmCs Set pkm settings related to crypto suites CBE showNeighborBs Display a neighbor BS descriptor from the handover database CBE showPsc Show the Power Saving Classes information CBE createPsc Declare a PSC in the local PSCD CBE changeSleepId Modify a PSC config CBE modifyPsc Modify a PSC config CBE deletePsc Delete a PSC from the PSC database CBE activatePsc Activate a PSC CBE deactivatePsc Deactivate a PSC CBES setQosRedUlDefaultProfile Configure the uplink RED drop profile for Sf without max latency CBES setQosRedUlMaxLatencyProfile Configure the uplink RED drop profile for Sf with non null max latency CBES setQosRedUlDefault Configure congestion control in uplink for Sf without max latency CBES showQosUl Show Ul Qos configuration CBES showSsPhyStatsDl display the downlink physical statistics CBES startSs start the 802.16 MAC CBES stopSs stop the 802.16 MAC CBES resetSs stop and restart the 802.16 MAC CBES showSs Show SS information CBES performHandover Jump to a neighbor BS (small cell jump) CBES requestPowerModeChange Request power control mode change CBES setTxPower Set TX power to specified value CBES setMaxTxPower set Max Tx Power CBES showSsAuth Show SS Authorization CBES resetSsAuth reset SS Authorization CBES showSa Show Security Association CBES showRfRx Show the radio frequency receiver configuration CBES showRfTx Show the radio frequency transmitter configuration CBES showRfConfig Show radio frequency configuration CBES showLinkAdaptationDl Show the downlink adaptation configuration CBES setLinkAdaptationDl Configures the downlink adaptation CBES showPhyStatsRx Show the downlink physical stats CBES setRfTx Set radio frequency / base band parameters for TX CBES showPacketFlow Show the packet flow statistics CBES resetPacketFlow Reset the packet flow statistics CBES showVersion Show the system version CBES setGpiosState Set the state of GPIO manager CBES setIdleMode Start IDLE mode CBES showProvisionedPsc Show the provisioned Power Saving Class config CBES setProvisionedPsc Set the full provisioned Power Saving Class config CBES modifyProvisionedPsc Modify some param of the provisioned Power Saving Class config CBES crashMeNow test delivery of fatals CBES sendRssiToHost test delivery of rssi level changes notifications to host via THP CBES enableSendingRssiToHost test enable the sending of RSSI range CBES setDebugAsicOutput Configure the ASIC debug output signals CBES setScanning Configure periodic scanning CBES showScanning Display periodic scanning parameters CBES setHandover Configure handover trigger CBES showHandover Display handover trigger parameters CBES showNeighborBsStat Diplay statistics of neighbor BS CBES setIotMode set IOT mode CBES showIotMode show the current IOT mode CBES enableMrctMs11 Enable MRCT MS-11.1 MS-11.2 compliance CBES enableMrctMs05 Enable MRCT MS-05.1 MS-05.2 compliance CBES setDeviceMode set DEVICE mode CBES showDeviceMode show the current DEVICE mode CBES addChannelToScanner Add a new channel to the scanning list CBES showScanner Show the the scanning list CBES removeChannelFromScanner Remove a channel from the scanning list CBES clearScannerChannels Reset all scanner entries CBES showHomeNsp Display the current home NSP CBES setHomeNsp Set the home NSP with on NSP ID CBES showProvisionedNAPs Show the list of authorized and forbidden NAPs (CAPL) CBES addProvisionedNAP Add a provisioned Nap CBES removeProvisionedNAP Remove a provisioned Nap CBES clearProvisionedNAPs Clear the list of provisioned NAPs CBES showProvisionedNSPs Show the list of authorized and forbidden NSPs CBES addProvisionedNSP Add a provisioned NSP CBES removeProvisionedNSP Remove a provisioned NSP CBES clearProvisionedNSPs Clear the list of provisioned NSPs CBES showNdssConfig Show NDSS parameters. CBES setNdssConfig Set NDSS parameters. CBES showDurationTimeout Show scan duration timeout. CBES setDurationTimeout Set scan duration timeout. CBES showHoldingTimeout Show scan holding timeout. CBES setHoldingTimeout Set scan holding timeout. CBES forceScanning Forces scanning when NDSS is in Zzz mode CBES connect Forces connection to BS CBES showPlatform Show the configuration of the platform CBES setWatchDog Enable or Disable watchdog CBES showWatchDog Show watchdog status }}}