| 1 | == Software == |
| 2 | |
| 3 | === Site Software Installation Instructions === |
| 4 | |
| 5 | The Instructions in the Airspan Installation Guide (shipped with airspan BS) talk about the process of Installation. |
| 6 | The components for the software installation are: |
| 7 | |
| 8 | 1. Netspan Management Software |
| 9 | 2. Netspan Software License |
| 10 | 3. Windows server SP2 2008 Edition License to run the Netspan software |
| 11 | 4. Server/laptop to run Windows machine |
| 12 | |
| 13 | The Airspan BS ''' does not power ON by default '''. |
| 14 | |
| 15 | Refer to Page 56 of Installation Guide in conjunction to these instructions. |
| 16 | |
| 17 | |
| 18 | Change the management IP and VLAN configuration to your site addressing scheme. |
| 19 | |
| 20 | Contact seskar (at) winlab (dot) rutgers (dot) edu to initiate license acquisition for netspan. |
| 21 | |
| 22 | Place the GPS device connected to Air4G-W24 in an area where it can obtain a Lock. |
| 23 | |
| 24 | |
| 25 | === Configuring Base station profile === |
| 26 | After uploading the license, |
| 27 | - Create a discovery task: Server -> Discovery parameters -> Add |
| 28 | (the form fields should match the BS configuration) |
| 29 | - Wait for the discovery to take place |
| 30 | - After a while, the BS should be visible under Configuration |
| 31 | management -> Node -> Node |
| 32 | - Select it and click on Edit |
| 33 | - Configure everything according to the "golden config" (basically |
| 34 | the default settings), except for the IP address and RF profile which |
| 35 | are site-specific |
| 36 | - Make sure that the form field "Ready for service" says "Ready for service" |
| 37 | - Click OK |
| 38 | - Wait for the provisioning to complete (it takes a couple of minutes) |
| 39 | - If the provisioning fails, the BS is probably in "maintenance" |
| 40 | mode and must be switched to "out of service" with the |
| 41 | following steps, if needed: |
| 42 | - Select the BS and click on Manage |
| 43 | - Go to the "State and control" page |
| 44 | - Under "16e BS service state" select "Set out of service" |
| 45 | - Click OK and wait, now the provisioning should take place |
| 46 | |
| 47 | - Switch the "16e BS service state" to "in service", following the |
| 48 | above procedure |
| 49 | - Now netspan should report all green and the BS should be fully up |
| 50 | and running |
| 51 | |
| 52 | ''' Note ''' that the BS cannot be moved from "maintenance" to "in service" |
| 53 | directly , so it must be put first into "out of service" state, and then finally "in |
| 54 | service". |