Version 10 (modified by 8 years ago) ( diff ) | ,
---|
AirSynergy 2000
Table of Contents
Hardware Installation
AirSynergy Connections:
1. Power Connect power cable to -48 power supply with the provided cable; [Mean Well SP3XXX] ![]()
2. Networking Insert SFP+ and connect; list of supported SFP+s 3. Serial Console (optional) If needed for debugging
Fully connected AirSynergy without weatherproofing covers should look like this:
Power Supply
The AirSynergy supports direct connection to a -48VDC nominal power source.
Operating Voltage Range: -40.5 to 57 VDC
A power supply capable of 2A or greater is recommended (eg. Mean Well CLG-100-48).
Power Connector/Cable
The base station end of the power supply cable uses a Molex 0039012040 housing (Digikey: WM3701-ND) with Molex 0039000039 pins (Digikey: WM2501-ND). The power supply cable itself is 4-conductor 16 AWG.
Power Connector Housing:
Power Connector Pinout:
Compatible SFP+ Adapters
The following SFP+ adapters were tested for compatibility with the AirSynergy.
NOTE: Fiber connections were tested with the following adapters on the "server" side:
Manufacturer Model Note Intel FTLX8571D3BCV-IT multi-mode fiber Intel FTLX1471D3BCV-IT single-mode fiber
CAT5/CAT6 (Copper Gigabit Ethernet)
Manufacturer Model Note Avago ABCU-5730ARZ 1G (T)
Multi-mode Fiber
Manufacturer Model Note Dell FTLX8571D3BCL 1G/10G (SR) Finisar FTLX8571BCV Intel AFBR-703SDZ-IN2 Iwnetworks IW-TRSFPL-SR Finisar SFP-10GSR-85 Trendnet TEG-MGBSX Cisco 1000BASE-SX
Single-mode Fiber
Manufacturer Model Note Dell FTLX1471D3BCL
Software Installation
Attachments (3)
- airsynergy_connections.jpg (150.3 KB ) - added by 7 years ago.
- airsynergy_power_cable.jpg (60.6 KB ) - added by 7 years ago.
- power_supply.png (322.1 KB ) - added by 7 years ago.
Download all attachments as: .zip