Hardware Installation
AirSynergy Connections:
1. Power Connect power cable to -48 power supply with the provided cable; [Mean Well SP3XXX] ![]()
2. Networking Insert SFP+ and connect; list of supported SFP+s 3. Serial Console (optional) If needed for debugging
Fully connected AirSynergy without weatherproofing covers should look like this:
Power Supply
The AirSynergy supports direct connection to a -48VDC nominal power source.
Operating Voltage Range: -40.5 to 57 VDC
A power supply capable of 2A or greater is recommended (eg. Mean Well CLG-100-48).
Power Supply Connector/Cable
The base station end of the power supply cable uses a Molex 0039012040 housing (Digikey: WM3701-ND) with Molex 0039000039 pins (Digikey: WM2501-ND). The power supply cable itself is 4-conductor 16 AWG.
Power Connector Housing:
Power Connector Pinout:
Compatible SFP+ Adapters
The following SFP+ adapters were tested for compatibility with the AirSynergy.
NOTE: Fiber connections were tested with the following adapters on the "server" side:
Manufacturer Model Note Intel FTLX8571D3BCV-IT multi-mode fiber Intel FTLX1471D3BCV-IT single-mode fiber
CAT5/CAT6 (Copper Gigabit Ethernet)
Manufacturer Model Note Avago ABCU-5730ARZ 1G (T)
Multi-mode Fiber
Manufacturer Model Note Dell FTLX8571D3BCL 1G/10G (SR) Finisar FTLX8571BCV Intel AFBR-703SDZ-IN2 Iwnetworks IW-TRSFPL-SR Finisar SFP-10GSR-85 Trendnet TEG-MGBSX Cisco 1000BASE-SX
Single-mode Fiber
Manufacturer Model Note Dell FTLX1471D3BCL
Serial Debug
The base station has a 9 pin connector (hidden behind a black hex bolt next to the port marked "ETH") which allows access to the serial. This is useful for recovery purposes when the base station does not respond via software, SSH, or web interfaces. See Airspan LTE Base Station Serial Console for information on cable construction and serial port parameters. Note that the AirSyngery only has the "asil8xx" serial port functioning (TX2,RX2 in the referenced document). However, the other internal module can still be accessed via ssh once logged into the asil8xx module via the serial port.